Difference between revisions of "83Plus:Ports:22"
From WikiTI
Thepenguin77 (Talk | contribs) |
(precedence) |
||
Line 18: | Line 18: | ||
== Comments == | == Comments == | ||
This port does not exist on the standard 83 Plus. See ports [[83Plus:Ports:05|5]] and [[83Plus:Ports:16|16]] instead. Execution of code from a page above this port's value and below the value in [[83Plus:Ports:23|Port 23]] will cause the calculator to reset. | This port does not exist on the standard 83 Plus. See ports [[83Plus:Ports:05|5]] and [[83Plus:Ports:16|16]] instead. Execution of code from a page above this port's value and below the value in [[83Plus:Ports:23|Port 23]] will cause the calculator to reset. | ||
+ | |||
+ | If port 23h is less than 22h, 22h takes precedence; that is, all pages will be executable. |
Revision as of 20:13, 20 February 2013
This port only exists as a distinct port on the TI-83 Plus Silver Edition, the TI-84 Plus, and the TI-84 Plus Silver Edition. On the standard TI-83 Plus, it acts as a shadow of port 02. |
This port is protected, which means user programs cannot ordinarily write to it directly. |
Synopsis
Port Number: 22h
Function: Flash Execution Lower Limit
This port controls the first of two flash page execution limits.
Read Values
- [00h - FFh]: Flash Pages below this value have execution permission. This is always set to 08 in TIOS.
Write Values
- [00h - FFh]: The new execution limit. You must enable flash access through port 14 first.
Comments
This port does not exist on the standard 83 Plus. See ports 5 and 16 instead. Execution of code from a page above this port's value and below the value in Port 23 will cause the calculator to reset.
If port 23h is less than 22h, 22h takes precedence; that is, all pages will be executable.