− | [[Category:83Plus:BCALLs:By Name|Chk_Batt_Low]][[Category:83Plus:BCALLs:By Name:Utility|Chk_Batt_Low]][[Category:83Plus:BCALLs:By Address|50B3 | + | [[Category:83Plus:BCALLs:By Name|Chk_Batt_Low]][[Category:83Plus:BCALLs:By Name:Utility|Chk_Batt_Low]][[Category:83Plus:BCALLs:By Address|50B3 - Chk_Batt_Low]] |
== Synopsis == | == Synopsis == | ||
'''Official Name:''' Chk_Batt_Low | '''Official Name:''' Chk_Batt_Low |
Revision as of 01:52, 13 May 2005
Synopsis
Official Name: Chk_Batt_Low
BCALL Address: 50B3,50B6
Check the batteries.
Inputs
- None
Outputs
- Z=1: Batteries are low
- Z=0: Batteries are good
Registers Destroyed
- All
Comments
This is not just checking bit 0 of port 2. It puts the calculator into a special mode, creates a delay, polls bit 0 of port 2, and puts the calculator back to normal.
Example
B_CALL Chk_Batt_Low ret z B_CALL ChkFindSym ret c ld a,b or a ret nz AppOnErr errHand B_CALL Arc_Unarc AppOffErr errHand: ret