Revision as of 03:32, 28 March 2005

Synopsis

Official Name: LdHLInd

BCALL Address: 4009

Stores the value at (HL) to register HL.

Inputs

  • HL: pointer to bytes to load

Outputs

  • HL: value located at input (HL)

Registers Destroyed

  • AF

Comments

Useful utility call. Equivalent code located in example.

Example

LdHLInd:
 ld a,(hl)
 inc hl
 ld h,(hl)
 ld l,a
 ret