Synopsis
Official Name: LoadAIndPaged
BCALL Address: 8051
Reads a byte into register A on page A at address HL.
Inputs
- A = page
- HL = address
Outputs
- A = byte read
Destroys
- All registers preserved
- Destroys contents of memory at 8100 (ramCode)
Comments
Simple enough to implement yourself if speed is important.
Example
ld a,0 ld hl,4000 B_CALL LoadAIndPaged ;should return a=DB (at least on OS version 1.18)