Difference between revisions of "83Plus:BCALLs:423D"

From WikiTI
Jump to: navigation, search
 
m (Category: fp util)
Line 1: Line 1:
[[Category:83Plus:BCALLs:By Name:Utility|GETCONOP1]] [[Category:83Plus:BCALLs:By Name|GETCONOP1]] [[Category:83Plus:BCALLs:By Address|423D - GETCONOP1]]
+
[[Category:83Plus:BCALLs:By Name:FP_Util|GETCONOP1]] [[Category:83Plus:BCALLs:By Name|GETCONOP1]] [[Category:83Plus:BCALLs:By Address|423D - GETCONOP1]]
 
== Synopsis ==
 
== Synopsis ==
 
'''Official Name:''' GETCONOP1
 
'''Official Name:''' GETCONOP1

Revision as of 08:26, 31 March 2005

Synopsis

Official Name: GETCONOP1

BCALL Address: 423D

Loads one of seven different commonly used constants to op1.

Inputs

  • a = constant type
  • where constant type is
  • a=0 180/PI
  • a=1 PI/2
  • a=2 PI/4
  • a=3 Log(e)
  • a=4 PI
  • a=5 PI/180
  • a=6 ln(10)

Outputs

  • op1 = constant

Registers Destroyed

  •  ??

Example

 ld     a,4     ;PI
 B_CALL GETCONOP1
 

After the BCALL:

 8478: 00 80 31 41 59 26 53 58 98