Difference between revisions of "83Plus:Ports:03"
From WikiTI
m |
m |
||
Line 1: | Line 1: | ||
− | [[Category:83Plus:Ports:By_Address|03 - Interrupt Mask]] | + | [[Category:83Plus:Ports:By_Address|03 - Interrupt Mask]] [[Category:83Plus:Ports:By_Name|Interrupt Mask]] |
− | [[Category:83Plus:Ports:By_Name|Interrupt Mask]] | + | |
== Synopsis == | == Synopsis == | ||
'''Port Number:''' 03h | '''Port Number:''' 03h |
Revision as of 21:17, 29 March 2005
Contents
Synopsis
Port Number: 03h
Function: Interrupt Masking Port
This port controls what devices will be allowed to trigger interrupts.
Read Values
- Bit 0: Set if pressing the ON key will generate an interrupt.
- Bit 1: Set if the first hardware timer will generate an interrupt (range: 108Hz-512Hz).
- Bit 2: Set if the second hardware timer will generate an interrupt (range: 216Hz-1024Hz).
- Bit 4: Set if the linkport will generate an interrupt.
Write Values
- Bit 0: Set 1 to enable the ON key. Set 0 to disable it.
- Bit 1: Set 1 to enable the first hardware timer. Set 0 to disable it.
- Bit 2: Set 1 to enable the second hardware timer. Set 0 to disable it.
- Bit 3: Set 1 to enable the LCD. Set 0 to turn off the LCD.
- Bit 4: Set 1 to enable the linkport interrupt. Set 0 to disable it. (Does not completely disable the linkport.)
Comments
For normal operation, write 0B (00001011) to this port.
Example
This example shows how to do a soft powerdown (similar to the auto powerdown) on the calculator. This may or may not wipe the LCD screen, so you should first copy it's contents to a buffer like saveSScreen and then copy it back afterwards.
push af ld a, 11h ;Enable linkport, ON key. Disable timer. Turn off LCD. out (3), a halt ;Wait for an interrupt (either ON key or insert link cable). ld a, 0Bh ;Enable ON key, timer. Disable linkport. Turn on LCD. out (3), a pop af