83Plus:Ports:02: Difference between revisions

From WikiTI
Jump to navigationJump to search
No edit summary
 
m →Synopsis: fixed a typo and added info on flash apps
Line 6: Line 6:
'''Function:''' Calculator Status Information
'''Function:''' Calculator Status Information


This port reports various status information, including battery strenght, LCD driver status, and calculator type.
This port reports various status information, including battery strength, LCD driver status, and calculator type.


=== Read Values ===
=== Read Values ===
* Bit 0: Set if the batteries are good. Reset if the batteries are low. The calculator will refuse to Garbage Collect when the batteries are low.
* Bit 0: Set if the batteries are good. Reset if the batteries are low. The calculator will refuse to Garbage Collect or receive a FLASH App when the batteries are low.
* Bit 1: Set if the LCD Driver can receive a command. Reset otherwise. This is basically the inverse of bit 7 from Port 10h.
* Bit 1: Set if the LCD Driver can receive a command. Reset otherwise. This is basically the inverse of bit 7 from Port 10h.
* Bit 5: Set for TI-84+ and TI-84+ SE calculators. Reset for TI-83+ and TI-83+ SE calculators.
* Bit 5: Set for TI-84+ and TI-84+ SE calculators. Reset for TI-83+ and TI-83+ SE calculators.

Revision as of 02:19, 30 March 2005

Synopsis

Port Number: 02h

Function: Calculator Status Information

This port reports various status information, including battery strength, LCD driver status, and calculator type.

Read Values

  • Bit 0: Set if the batteries are good. Reset if the batteries are low. The calculator will refuse to Garbage Collect or receive a FLASH App when the batteries are low.
  • Bit 1: Set if the LCD Driver can receive a command. Reset otherwise. This is basically the inverse of bit 7 from Port 10h.
  • Bit 5: Set for TI-84+ and TI-84+ SE calculators. Reset for TI-83+ and TI-83+ SE calculators.
  • Bit 7: Reset for a TI-83+ Basic. Set for everything else.

Write Values

  • No useful effect.

Comments

See Port 21h for how to distinguish the 84+ Basic from the 84+ SE.

Example

Battery checking

 push af
 in a, (2)
 and 01h
 call nz, BatteriesGood
 call z, BatteriesLow
 pop af

LCD Testing

 push af
WaitLoop:
 in a, (2)
 and 02h
 jr z, WaitLoop
 ;Send a command, like 03 (LCD "On").
 call LCDIsReady
 pop af

Device checking

This example also uses Port 21h.

 in a, (2)
 rlca ;Roll bit 7 into carry.
 jp c, Regular83Plus
 rlca
 rlca ;Roll bit 5 into carry.
 jp nc, Silver83Plus
 in a, (21h)
 and 01h
 jp z, Regular84Plus
 jp nz, Silver84Plus


Credits and Contributions

  • Michael Vincent: Documentation of port 2 located here.