Synopsis
Unofficial Name: SendReadyPacket
BCALL Address: 4F24
Sends the ready packet over the link port and receives acknowledgement.
Inputs
- Bits 1-4 of iy+1Bh reset
Outputs
- None
Destroys
- All
Comments
This BCALL will throw ERR:LINK if any problems are found.
If any of bits 1-4 of iy+1Bh are set, this routine immediately returns. If the other calculator responds with a machine ID of 83h, 3,(iy+1Bh) is set.