Difference between revisions of "83Plus:BCALLs:406F"
From WikiTI
(No difference)
|
Latest revision as of 17:27, 22 April 2005
Synopsis
Official Name: FPSub
BCALL Address: 406F
Subtracts the floating point number in OP2 from the floating point number in OP1 and stores the result in OP1.
Inputs
- OP1 = floating point number
- OP2 = floating point number
Outputs
- OP1 = OP1 - OP2
- OP2 = - OP2
Registers Destroyed
- AF, BC, DE, HL
Example
B_CALL OP1Set3 ;OP1=floating point 3 B_CALL OP2Set2 ;OP2=floating point 2 B_CALL FPSub ;returns with OP1=floating point 1